6 tips: How to find the right ventilation for your network cabinet

27.06.2024 (Last update: 18.12.2025)

Do you always need professional cooling systems such as water cooling, or is simple network cabinet ventilation sufficient? We believe that every situation requires an individual solution.

It is not necessarily the case that a rack always has to be cooled by a modern cooling system using water or special refrigerants. The best way to determine which cooling system is suitable for operating your own IT infrastructure is to measure its size. The more IT hardware is in operation, the more heat is produced, which must be dissipated.

Passive or active network cabinet ventilation may be sufficient for individual racks. To help you find the right solution for your applications, we would like to give you six tips.

Side note: What is the difference between active and passive ventilation?

Passive network cabinet ventilation is easy to explain: Racks with ventilation slots or even perforated elements can already use enough room air to sufficiently cool the server and hardware components. Active ventilation is required when cooling via the room air is no longer sufficient. Passive cooling is sufficient because it does not require any additional (electrical) energy to cool the IT systems.

Get comprehensive advice now!

6 tips: How to find the right network cabinet ventilation for your needs

1. Passive or active cooling?

In most cases, passive cooling without active support is not sufficient. The open surfaces allow dust and other particles to penetrate the hardware. Whether active or passive cooling is required depends primarily on the power to be dissipated and the ambient conditions.

2. Check the environment (or have it checked)

However, before you decide on a cooling solution, you should first check the environment yourself or have it checked by a professional. Dust particles are not the only problem when it comes to cooling. Room temperature and humidity also play a role. Even a rack that is placed too close to a wall can heat up very quickly – either due to its own heat build-up or heat radiation from the wall.

3. Calculate the cooling capacity correctly

How much cooling capacity do you actually need? You should not decide on a specific network cabinet ventilation system without knowing this value. Normally, the required cooling capacity is specified in watts on each individual device. However, simply adding up the values can still produce incorrect results. You should take so-called overhead factors into account, e.g. additional heat sources from the environment or hardware overload. However, the overhead factor is an estimate. On average, you should add around 20% more cooling capacity than the sum of the manufacturer's specifications.

4. Should you use air cooling?

Filter fans and filter fans with an increased protection class up to IP54 (‘roof fans’) may be sufficient for small and medium-sized IT environments. They are energy-efficient and do not incur high costs. They can be an inexpensive solution, especially for the use of individual racks in edge computing.

However, the disadvantages are that the cooling capacities are very limited and at the same time there are negative effects on the ambient conditions (e.g. room temperature or humidity). A simple fan can be used up to a cooling capacity of 2.5 to 3 kW. Above this, you should opt for a water-cooled solution such as our WallCooler.

5. How about water cooling?

Unlike normal network cabinet ventilation, cooling with water or a water-glycol mixture offers a much wider range of performance. The WallCooler from Schäfer IT-Systems achieves a cooling capacity of 4 kW and is very energy-efficient. The hot water cooling system of the High Cap Edge is particularly energy-efficient and environmentally friendly, with a capacity of 50 kW. If you require very high cooling capacity, the cold water technology of the Heat Exchanger is the best choice. It can deliver a capacity of up to 300 kW. Schäfer IT-Systems offers you a range of other cooling technologies using water or refrigerants that go beyond simple network cabinet ventilation. We offer individual solutions for every requirement.

6. Use monitoring

Even if you have opted for suitable network cabinet ventilation or a powerful cooling system with water, you should still use monitoring technologies. Monitoring can help you use cooling more energy-efficiently. While cooling systems can be ramped up during IT system performance peaks, less cooling power is required when demand is lower. This can save costs and make the operation of your IT infrastructure significantly more sustainable.