water cooled High Cap Edge

High Cap Edge
with Direct Hot Water Cooling

High Cap Edge – the modern solution in hot water cooling. This system is not only a technological advancement in direct water cooling but also a significant step toward building an energy-efficient and environmentally friendly data center.

High Cap Edge harnesses all the advantages of efficient warm water cooling. The system delivers outstanding energy efficiency with direct hot water cooling, supporting temperatures of up to 65°C. The technical specifications of High Cap Edge are impressive: from a compact design that allows flexible placement to a wide range of configuration options – everything can be individually tailored to your specific needs.

With customized solutions, SCHÄFER IT-Systems ensures that High Cap Edge integrates seamlessly into your existing IT infrastructure. We provide optimal consulting and support during planning because we know every data center is unique. Our experts and partners are always available to assist you with your project.

Basic configuration

  • Rack: 43 or 47 U
  • Slot-InCooler
  • In-RackCooler
  • Hydraulic distributor
  • PDU (Power Distribution Unit)

 

Cooling capacity

  • Direct hot water cooling: 50 kW @ 10K spread
  • Air cooling: up to 10 kW @ 6K spread

 

Dimensions

  • Width: 800 mm (19" Format)
  • Height: 2,000 mm or 2,200 mm
  • Plinth: 100 mm or 200 mm
  • Depth: 1,200 mm

Temperatures

  • Hot water cooling: up to 65° C
  • Server supply / exhaust air: 27 . . . 45 ° C
  • External air: -30° C bis 40° C

 

Interfaces

  • Electric: CEE 32A 400V 3ph
  • Waste heat utilization: 2x DN32 (R 1.1/4")
  • In-RackCooler: Modbus TCP, RTU, http, BACnet IP (optional), SNMP V2 und V3

 

Additional modules

  • UPS + Powerbox
  • Rack fire suppression
  • Monitoring and sensors
  • Access control

What Hot Water Cooling Can Do

The hot water cooling of the High Cap Edge offers numerous advantages, with energy and cost efficiency at the forefront. Hot water cooling significantly reduces the operating costs of your data center. In addition, this system is a prime example of IT sustainability, as it minimizes environmental impact.

Reliability and Performance

High Cap Edge excels with outstanding reliability and optimized performance. Thanks to its easy scalability and flexibility, it allows you to effortlessly meet the growing demands of your business.

Cost Reduction

By using hot-water-cooled servers and water-conditioned slot-in coolers, costs for air conditioning units are reduced, while waste heat can be reused. Alternatively, this concept enables free cooling throughout the year. The closed design offers a compact overall solution that can be expanded at any time by adding further units.

Why SCHÄFER IT-Systems

Years of Experience and Expertise

With our many years of experience and expertise in cooling technology and IT infrastructure, we are the ideal partner. SCHÄFER IT-Systems is proud to provide our customers not only with first-class products but also with outstanding service. With our support and the High Cap Edge, you are perfectly equipped to meet the challenges of the future.

At SCHÄFER IT-Systems, we are committed to making a contribution with our products so that you can design your data center or edge computing solutions in an environmentally friendly way. Our goal is to achieve measurable cost and energy savings through the use of products such as High Cap Edge, which is based on hot water cooling.

We understand the challenges that data centers and operators face and, with our iQdata brand, offer customized solutions. You can also benefit from our water cooling systems with lower temperatures or our air-cooled systems. We will be happy to advise you!

Get in Touch Now!

Are you ready to take advantage of hot water cooling with High Cap Edge? To receive more information or to arrange a personal consultation, don’t hesitate to contact us today.

At SCHÄFER IT-Systems, we are convinced that High Cap Edge represents the future of hot water cooling in data centers. Your IT infrastructure will become more environmentally friendly, more efficient, and more cost-effective to operate. With SCHÄFER IT-Systems and High Cap Edge, you step into the future.

Let us advise you today and find out whether hot water cooling is the right solution for your requirements – or whether another cooling solution might be the better alternative.

We look forward to hearing from you.

We are looking forward to your message

Product
Persönliche Informationen
Your message
Privacy policy
Text

All fields marked with an * are compulsory. We take the utmost care when handling your personal data and comply with the latest data protection legislation.

Send
FAQ
What is the maximum temperature supported by High Cap Edge?

The High Cap Edge's hot water cooling system supports temperatures up to 65°C. This ensures high energy efficiency and optimal cooling performance.

Can the High Cap Edge be integrated into any IT infrastructure?

The High Cap Edge is flexibly configurable and can be individually adapted to the specific needs of any IT infrastructure.

What are the advantages of hot water cooling?

The High Cap Edge's hot water cooling system offers significant energy and cost savings. It improves reliability, enables higher performance of your IT systems, and contributes to environmentally friendly operation.